Signed-off-by: Sgr A* VMT <1611902585@qq.com>
This commit is contained in:
Sgr A* VMT
2024-02-07 12:24:21 +00:00
committed by Gitee
parent d5f021844f
commit 23b2bab9cd
2 changed files with 86 additions and 74 deletions

View File

@@ -6,64 +6,70 @@ This tutorial aims to optimize temperature compensation parameters to reduce tem
```ini
[gcode_macro DATA_SAMPLE]
gcode:
{% set bed_temp = params.BED_TEMP|default(90)|int %}
{% set nozzle_temp = params.NOZZLE_TEMP|default(250)|int %}
{% set min_temp = params.MIN_TEMP|default(40)|int %}
{% set max_temp = params.MAX_TEMP|default(70)|int %}
M106 S255
TEMPERATURE_WAIT SENSOR='temperature_sensor IDM_coil' MAXIMUM=40
TEMPERATURE_WAIT SENSOR='temperature_sensor IDM_coil' MAXIMUM={min_temp}
M106 S0
G28
G0 Z1
M104 S250
M140 S95
G4 P1000
M104 S{nozzle_temp}
M140 S{bed_temp}
TEMPERATURE_WAIT SENSOR='temperature_sensor IDM_coil' MINIMUM={min_temp}
IDM_STREAM FILENAME=data1
TEMPERATURE_WAIT SENSOR='temperature_sensor IDM_coil' MINIMUM=70
TEMPERATURE_WAIT SENSOR='temperature_sensor IDM_coil' MINIMUM={max_temp}
IDM_STREAM FILENAME=data1
M104 S0
M140 S0
M106 S255
G0 Z80
TEMPERATURE_WAIT SENSOR='temperature_sensor IDM_coil' MAXIMUM=40
TEMPERATURE_WAIT SENSOR='temperature_sensor IDM_coil' MAXIMUM={min_temp}
M106 S0
G28 Z0
G0 Z2
M104 S250
M140 S95
M104 S{nozzle_temp}
M140 S{bed_temp}
G4 P1000
IDM_STREAM FILENAME=data2
TEMPERATURE_WAIT SENSOR='temperature_sensor IDM_coil' MINIMUM=70
TEMPERATURE_WAIT SENSOR='temperature_sensor IDM_coil' MINIMUM={max_temp}
IDM_STREAM FILENAME=data2
M104 S0
M140 S0
M106 S255
G0 Z80
TEMPERATURE_WAIT SENSOR='temperature_sensor IDM_coil' MAXIMUM=40
TEMPERATURE_WAIT SENSOR='temperature_sensor IDM_coil' MAXIMUM={min_temp}
M106 S0
G28 Z0
G0 Z3
M104 S250
M140 S95
M104 S{nozzle_temp}
M140 S{bed_temp}
G4 P1000
IDM_STREAM FILENAME=data3
TEMPERATURE_WAIT SENSOR='temperature_sensor IDM_coil' MINIMUM=70
TEMPERATURE_WAIT SENSOR='temperature_sensor IDM_coil' MINIMUM={max_temp}
IDM_STREAM FILENAME=data3
M104 S0
M140 S0
M106 S255
G0 Z80
TEMPERATURE_WAIT SENSOR='temperature_sensor IDM_coil' MAXIMUM=40
TEMPERATURE_WAIT SENSOR='temperature_sensor IDM_coil' MAXIMUM={min_temp}
M106 S0
G28 Z0
G0 Z5
M104 S250
M140 S95
M104 S{nozzle_temp}
M140 S{bed_temp}
G4 P1000
IDM_STREAM FILENAME=data4
TEMPERATURE_WAIT SENSOR='temperature_sensor IDM_coil' MINIMUM=70
TEMPERATURE_WAIT SENSOR='temperature_sensor IDM_coil' MINIMUM={max_temp}
IDM_STREAM FILENAME=data4
M104 S0
M140 S0
```
**Step 2:** Execute the macro. This will generate four files (data1, data2, data3, data4) in the klipper folder. This process takes a long time.
**Step 2:** Execute `DATA_SAMPLE BED_TMEP=<target bed temperature> NOZZLE_TEMP=<target nozzle temperature> MIN_TEMP=<minimum temperature of sampling range> MAX_TEMP=<maximum temperature of samping range>`
if you dont input any parameter,it will run with default parameters(BED_TMEP=90 NOZZLE_TEMP=250 MIN_TEMP=40 MAX_TEMP=70).
This will generate four files (data1, data2, data3, data4) in the klipper folder. This process takes a long time.
**Step 3:** Move the four generated files to the IDM folder in your user directory.