using my own resonance tester algorithm
This commit is contained in:
@@ -11,14 +11,15 @@ Then, call the `AXES_SHAPER_CALIBRATION` macro and look for the graphs in the re
|
||||
|
||||
| parameters | default value | description |
|
||||
|-----------:|---------------|-------------|
|
||||
|FREQ_START|5|Starting excitation frequency|
|
||||
|FREQ_END|133|Maximum excitation frequency|
|
||||
|HZ_PER_SEC|1|Number of Hz per seconds for the test|
|
||||
|AXIS|"all"|Axis you want to test in the list of "all", "X" or "Y"|
|
||||
|SCV|printer square corner velocity|Square corner velocity you want to use to calculate shaper recommendations. Using higher SCV values usually results in more smoothing and lower maximum accelerations|
|
||||
|MAX_SMOOTHING|None|Max smoothing allowed when calculating shaper recommendations|
|
||||
|KEEP_N_RESULTS|3|Total number of results to keep in the result folder after running the test. The older results are automatically cleaned up|
|
||||
|KEEP_CSV|0|Weither or not to keep the CSV data file alonside the PNG graphs|
|
||||
|FREQ_START|5|starting excitation frequency|
|
||||
|FREQ_END|133|maximum excitation frequency|
|
||||
|HZ_PER_SEC|1|number of Hz per seconds for the test|
|
||||
|ACCEL_PER_HZ|None|accel per Hz value used for the test. If unset, it will use the value from your `[resonance_tester]` config section (75 is the default)|
|
||||
|AXIS|"all"|axis you want to test in the list of "all", "X" or "Y"|
|
||||
|SCV|printer square corner velocity|square corner velocity you want to use to calculate shaper recommendations. Using higher SCV values usually results in more smoothing and lower maximum accelerations|
|
||||
|MAX_SMOOTHING|None|max smoothing allowed when calculating shaper recommendations|
|
||||
|TRAVEL_SPEED|120|speed in mm/s used for all the travel movements (to go to the start position prior to the test)|
|
||||
|Z_HEIGHT|None|Z height wanted for the test. This value can be used if needed to override the Z value of the probe_point set in your `[resonance_tester]` config section|
|
||||
|
||||
|
||||
## Graphs description
|
||||
|
||||
@@ -11,11 +11,12 @@ Then, call the `COMPARE_BELTS_RESPONSES` macro and look for the graphs in the re
|
||||
|
||||
| parameters | default value | description |
|
||||
|-----------:|---------------|-------------|
|
||||
|FREQ_START|5|Starting excitation frequency|
|
||||
|FREQ_END|133|Maximum excitation frequency|
|
||||
|HZ_PER_SEC|1|Number of Hz per seconds for the test|
|
||||
|KEEP_N_RESULTS|3|Total number of results to keep in the result folder after running the test. The older results are automatically cleaned up|
|
||||
|KEEP_CSV|0|Weither or not to keep the CSV data files alonside the PNG graphs|
|
||||
|FREQ_START|5|starting excitation frequency|
|
||||
|FREQ_END|133|maximum excitation frequency|
|
||||
|HZ_PER_SEC|1|number of Hz per seconds for the test|
|
||||
|ACCEL_PER_HZ|None|accel per Hz value used for the test. If unset, it will use the value from your `[resonance_tester]` config section (75 is the default)|
|
||||
|TRAVEL_SPEED|120|speed in mm/s used for all the travel movements (to go to the start position prior to the test)|
|
||||
|Z_HEIGHT|None|Z height wanted for the test. This value can be used if needed to override the Z value of the probe_point set in your `[resonance_tester]` config section|
|
||||
|
||||
|
||||
## Graphs description
|
||||
|
||||