@@ -11,10 +11,10 @@ Then, call the `AXES_SHAPER_CALIBRATION` macro and look for the graphs in the re
| parameters | default value | description | | parameters | default value | description |
|-----------:|---------------|-------------| |-----------:|---------------|-------------|
|FREQ_START|5|starting excitation frequency| |FREQ_START|None (default to `[resonance_tester]` value)|starting excitation frequency|
|FREQ_END|133|maximum excitation frequency| |FREQ_END|None (default to `[resonance_tester]` value)|maximum excitation frequency|
|HZ_PER_SEC|1|number of Hz per seconds for the test| |HZ_PER_SEC|1|number of Hz per seconds for the test|
|ACCEL_PER_HZ|None|accel per Hz value used for the test. If unset, it will use the value from your `[resonance_tester]` config section (75 is the default)| |ACCEL_PER_HZ|None (default to `[resonance_tester]` value)|accel per Hz value used for the test|
|AXIS|"all"|axis you want to test in the list of "all", "X" or "Y"| |AXIS|"all"|axis you want to test in the list of "all", "X" or "Y"|
|SCV|printer square corner velocity|square corner velocity you want to use to calculate shaper recommendations. Using higher SCV values usually results in more smoothing and lower maximum accelerations| |SCV|printer square corner velocity|square corner velocity you want to use to calculate shaper recommendations. Using higher SCV values usually results in more smoothing and lower maximum accelerations|
|MAX_SMOOTHING|None|max smoothing allowed when calculating shaper recommendations| |MAX_SMOOTHING|None|max smoothing allowed when calculating shaper recommendations|

View File

@@ -15,10 +15,10 @@ Then, call the `COMPARE_BELTS_RESPONSES` macro and look for the graphs in the re
| parameters | default value | description | | parameters | default value | description |
|-----------:|---------------|-------------| |-----------:|---------------|-------------|
|FREQ_START|5|starting excitation frequency| |FREQ_START|None (default to `[resonance_tester]` value)|starting excitation frequency|
|FREQ_END|133|maximum excitation frequency| |FREQ_END|None (default to `[resonance_tester]` value)|maximum excitation frequency|
|HZ_PER_SEC|1|number of Hz per seconds for the test| |HZ_PER_SEC|1|number of Hz per seconds for the test|
|ACCEL_PER_HZ|None|accel per Hz value used for the test. If unset, it will use the value from your `[resonance_tester]` config section (75 is the default)| |ACCEL_PER_HZ|None (default to `[resonance_tester]` value)|accel per Hz value used for the test|
|TRAVEL_SPEED|120|speed in mm/s used for all the travel movements (to go to the start position prior to the test)| |TRAVEL_SPEED|120|speed in mm/s used for all the travel movements (to go to the start position prior to the test)|
|Z_HEIGHT|None|Z height wanted for the test. This value can be used if needed to override the Z value of the probe_point set in your `[resonance_tester]` config section| |Z_HEIGHT|None|Z height wanted for the test. This value can be used if needed to override the Z value of the probe_point set in your `[resonance_tester]` config section|

View File

@@ -12,7 +12,7 @@ Here are the parameters available:
|CREATE_GRAPH|0|whether or not to record the accelerometer data and create an associated graph during the excitation| |CREATE_GRAPH|0|whether or not to record the accelerometer data and create an associated graph during the excitation|
|FREQUENCY|25|excitation frequency (in Hz) that you want to maintain. Usually, it's the frequency of a peak on one of the graphs| |FREQUENCY|25|excitation frequency (in Hz) that you want to maintain. Usually, it's the frequency of a peak on one of the graphs|
|DURATION|30|duration in second to maintain this excitation| |DURATION|30|duration in second to maintain this excitation|
|ACCEL_PER_HZ|None|accel per Hz value used for the test. If unset, it will use the value from your `[resonance_tester]` config section (75 is the default)| |ACCEL_PER_HZ|None (default to `[resonance_tester]` value)|accel per Hz value used for the test|
|AXIS|x|axis you want to excitate. Can be set to either "x", "y", "a", "b"| |AXIS|x|axis you want to excitate. Can be set to either "x", "y", "a", "b"|
|TRAVEL_SPEED|120|speed in mm/s used for all the travel movements (to go to the start position prior to the test)| |TRAVEL_SPEED|120|speed in mm/s used for all the travel movements (to go to the start position prior to the test)|
|Z_HEIGHT|None|Z height wanted for the test. This value can be used if needed to override the Z value of the probe_point set in your `[resonance_tester]` config section| |Z_HEIGHT|None|Z height wanted for the test. This value can be used if needed to override the Z value of the probe_point set in your `[resonance_tester]` config section|