more details about LIS2DW problems
This commit is contained in:
@@ -60,7 +60,6 @@ The following graphs show the effect of incorrect or uneven belt tension. Rememb
|
||||
| The A belt tension is slightly lower than the B belt tension. This can be quickly remedied by tightening the screw only about one-half to one full turn. |  |
|
||||
| B belt tension is significantly lower than the A belt. If you encounter this graph, I recommend going back to the [Voron belt tensioning documentation](https://docs.vorondesign.com/tuning/secondary_printer_tuning.html#belt-tension) for a more solid base. However, you could slightly increase the B tension and decrease the A tension, but exercise caution to avoid diverging from the recommended 110Hz base. |  |
|
||||
|
||||
|
||||
### Belt path problem
|
||||
|
||||
If there's an issue within the belt path, aligning and overlaying the curve might be unachievable even with proper belt tension. Begin by verifying that each belt has **the exact same number of teeth**. Then, inspect the belt paths, bearings, any signs of wear (like belt dust), and ensure the belt aligns correctly on all bearing flanges during motion.
|
||||
@@ -70,3 +69,13 @@ If there's an issue within the belt path, aligning and overlaying the curve migh
|
||||
| On this chart, there are two peaks. The first pair of peaks seems nearly aligned, but the second peak appears solely on the B belt, significantly deviating from the A belt. This suggests an issue with the belt path, likely with the B belt. |  |
|
||||
| This chart is quite complex, displaying 3 peaks. While all the pairs seem well-aligned and tension ok, there are more than just two total peaks because `[1]` is split in two smaller peaks. This could be an issue, but it's not certain. It's recommended to generate the [Axis Input Shaper Graphs](./axis_tuning.md) to determine its impact. |  |
|
||||
| This graph might indicate too low belt tension, but also potential binding, friction or something impeding the toolhead's smooth movement. Indeed, the signal strength is considerably low (with a peak around 300k, compared to the typical ~1M) and is primarily filled with noise. Start by going back [here](https://docs.vorondesign.com/tuning/secondary_printer_tuning.html#belt-tension) to establish a robust tension foundation. Next, produce the [Axis Input Shaper Graphs](./axis_tuning.md) to identify any binding and address the issue. |  |
|
||||
|
||||
### Spectrogram lightshow (LIS2DW)
|
||||
|
||||
The integration of LIS2DW as a resonance measuring device in Klipper is becoming more and more common, especially because some manufacturers are promoting its superiority over the established ADXL345. It's indeed a new generation chip that should be better to measure traditional "accelerations". However, a detailed comparison of their datasheets and practical measurements paints a more complex picture: the LIS2DW boasts greater sensitivity, but it has a lower sampling rate and produce significant aliasing that results in a "lightshow" effect on the spectrogram, characterized by multiple spurious resonance lines parallel to the main resonance, accompanied by intersecting interference lines that distort the harmonic profile.
|
||||
|
||||
For the belt graph, this can be problematic because it can introduce a lot of noise into the results and make them difficult to interpret, and it will probably tell you that there is a mechanical problem when there isn't.
|
||||
|
||||
| ADXL345 measurement | LIS2DW measurement |
|
||||
| --- | --- |
|
||||
|  |  |
|
||||
|
||||